7 Operation
32
100_0402_op_0003.fm
7.10 Starting
See blueprints: wc_gr001299
1. Disconnect all connections from the generator and put the main circuit
breaker in an open position (e2).
2. Open fuel shut-off valve (a).
Comment: Close the choke (b) if the engine is cold (pull out). Open the choke
if the engine is warm (push).
3. Put engine switch to “ON” (c1) and pull starter rope (d).
Comment: Do not start the engine if the oil level is low. In this case, check the
engine oil level and top off if necessary.
4. Open the choke while the engine is warming up (b).
5. Put main circuit breaker in the closed position (e1). Allow the engine to warm
up for a few minutes before connecting electrical equipment.
7.11 Stopping
See blueprints: wc_gr001299
1. Switch off all electrical equipment and tools and disconnect from the
generator.
2. Put the engine switch in the "OFF" position (c2).
3. Close the fuel shut-off valve.
Comment: To turn off quickly in cases of emergency, put the engine switch in
the "OFF" position (c2).
wc_gr001299
c1
c2
d
a
b
e2
e1