PST2 400 Installation
wc_tx001980gb.fm 21
3.7 Connecting the Power Supply
Draw power from a dedicated power outlet rated at 15 A or above.
Sharing the outlet with other equipment may cause overheating at the
branch outlet and could result in fire.
The grounded plug shall be connected as shown in the drawing.
NOTICE: Be sure to use a dedicated power supply with a ground
leakage circuit breaker.
Note: The shape of the plug may differ from that shown in the
illustration.
WARNING
Personal injury hazard. Electrical shock, shorting, fire, or unexpected starting of the
pump can occur.
Before connecting wires to the terminal, make certain the power supply is
turned off (circuit breaker, etc.)
Before inserting the power supply plug, make certain the power supply is turned
off (circuit breaker, etc.).
Do not use the pump with the cable assembly or plug connected loosely,