Installation PST2 400
22 wc_tx001980gb.fm
3.8 Cable Assembly
If a cable with cut insulation or other damage is submerged in the
water, there is a danger of damage to the pump, electrical leakage,
electrical shock, or fire.
Be careful not to let the cable assembly be cut or become twisted.
This may result in damage to the pump, electrical leakage, electrical
shock, or fire.
If it is necessary to submerge the connection wires of the cable
assembly in water, first seal the wires completely in a molded
protective sleeve, to prevent electrical leakage, electrical shock, or
fire.
Do not allow the cable assembly wires or power supply plug to
become wet.
Make sure the cable does not become excessively bent or twisted,
and does not rub against a structure in a way that might damage it.
If used in a deep-well installation, the cable assembly should be
secured every 6 m (20 ft).
CAUTION
Fire, electrical leakage or electrical shock hazard.
If it is necessary to extend the cable assembly, use a core size equal to or larger than
the original. This is necessary not only to avoid a performance drop, but to prevent
cable overheating.