Maintenance PST2 400
30 wc_tx002010gb.fm
Note: Worn lubricant and other waste products should be disposed of
by a qualified agent, in accord with applicable laws. The oil plug gasket
should be replaced each time the lubricant is inspected or changed.
Replacement Parts
The table lists the parts that need to be replaced periodically. Replace
these using the recommended frequency as a guideline.
Ref. Description Ref. Description
1 Oil Inlet 3 Oil Plug
2 Gasket 4 Allen Wrench
Pump Model Lubricant Capacity
PST2 400
PSTF2 400
160 ml (5.4 fl. oz.)
Part Replacement Frequency
Mechanical seal When lubricant in oil compartment becomes milky.
Lubricant (SAE 10W/20W) Every 2,000 hours or 12 months, whichever comes first.
Gasket Each time pump is disassembled or inspected.
Dust seal When ring is worn, and each time pump is disassembled or
inspected.
Sleeve When it becomes worn.