SPRAYING TROUBLESHOOTING  CLEAR THE SPRAY TIP
i
If the spray pattern becomes distorted or stops
spraying completely while the gun is triggered, the
spray tip could be clogged. Follow the steps below.
YOU WILL NEED
Scrap material / cardboard
Do not attempt to unclog or clean the tip with
your nger. High pressure uid can cause injection
injury.
1. Lock the spray gun.
2. Rotate spray tip 180 degrees from its current position.
i
If spray tip is dicult to rotate, relieve pressure by:
1) slowly turn PRIME/SPRAY knob to PRIME,
2) unlock the spray gun and
3) squeeze trigger while pointing at scrap material/
cardboard.
Release trigger, lock the spray gun, and try rotating
spray tip again.
3. Make sure the PRIME/SPRAY knob is turned to SPRAY.
Unlock the spray gun.
Point at a piece of scrap material / cardboard and squeeze
trigger until material comes out in a high pressure stream.
Release the trigger and lock the spray gun.
4. Rotate spray tip forward to the spray position.
Unlock the spray gun and resume spraying.