35
0
20
40
60
80
100
120
140
160
180
200
220
240
260
280
300
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
0
Recoil force N (Newton)*
1.98
1.83
1.57
1.30
1.10
0.91
0.79
0.66
0.53
0.46
This is the force acting on the gun and transmitted to the hand guiding the gun. Values for higher spraying
pressures can be calculated proportionally.
Attention: An additional turning moment may be caused when using pole guns. Hold pole gun with both hands.
Spray tip selection
Selection of the correct tip is essential for correct and efficient spraying. In many cases, the right tip can be
determined only by conducting a spray test.
Here are a few rules:
The spray fan must be uniform.
If streaks appear in the spray fan, the spraying pressure is too low or the viscosity of the material is too high.
Remedy: Increase pressure or thin the material. Each pump delivers a specific volume directly proportional to the
size of the tip:
Rule of thumb: large tip = low pressure
small tip = high pressure
A very wide range of tips is available with widely ranging spaying angles.
Pressure, bar
Theoretical recoil force diagram for Airless spray tips
Spray tip bore
mm
*Measured with water