EPG-SPRINT.
OPERATING MANUAL
VERSION 08/2010
ORDER NUMBER DOC 2305222
Properties of the characteristic Field of application/Remarks
Standard level (red)
Open-circuit voltage 100 kV
Maximum current 120 µA
(current limiting at 120 µA)
For poorly rechargeable types of
powder.
For high powder application.
For high application effectiveness.
This setting corresponds to the usual
Wagner high-voltage modules and
control units.
Medium level (blue)
Open-circuit voltage 100 kV
Maximum current 120 µA
For small surfaces.
For well rechargeable types of powder.
For metal powder.
To reduce the effects of overcoating such
as craters and orange peel.
Increasing the open-circuit voltage
allows for a greater distance between
the spray gun and the workpiece while
maintaining sufficient powder charging.
Soft level (black)
Open-circuit voltage 100 kV
Maximum current 80 µA
For very well rechargeable types of
powder.
For small powder application.
For post-coatings.

Table of Contents

Other manuals for WAGNER EPG-SPRINT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER EPG-SPRINT and is the answer not in the manual?

WAGNER EPG-SPRINT Specifications

General IconGeneral
BrandWAGNER
ModelEPG-SPRINT
CategoryControl Unit
LanguageEnglish

Related product manuals