EasyManuals Logo

WAGNER PXM User Manual

WAGNER PXM
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #58 background imageLoading...
Page #58 background image
58
PXM
OPERATING AND ASSEMBLY MANUAL
VERSION 08/2015 ORDER NUMBER DOC2350372
Home page
Cleaning
Settings
Alarm
Work-
station
FP
supply
Exhaust
system
Diagnosis
RP supply
Settings System
Duration
RP
supply
Standard
Yes
Operating mode
Message recovery system [sec]
Eco
No
Parameter: Explanation:
RP supply Yes: Reclaimed powder pump available
No: No reclaimed powder pump available
SAT: Speci c con guration for the SAT system
Operating mode Duration: Peristaltic pump operates continuously
Eco: Peristaltic pump works per cycle, that is, it
works during the "Feed time" adjustable time and
subsequently switches off for the "Break time"
adjustable time (power saving mode)
Message recovery system [sec] A timer runs at the speci ed time after the initial
feed after cleaning. After this time expires, a note is
displayed on the screen to plug the recovery hose
from the loss position to the recovery position.
MP
operation
MP
cleaning

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER PXM and is the answer not in the manual?

WAGNER PXM Specifications

General IconGeneral
BrandWAGNER
ModelPXM
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals