59
PXM
OPERATING AND ASSEMBLY MANUAL
VERSION 08/2015 ORDER NUMBER DOC2350372
Home page
Cleaning
Settings
Alarm
Work-
station
FP
supply
Exhaust
system
DiagnosisSettings System
No
RP
supply
Standard
Duration Eco
Yes
Standard
RP supply
Operating mode
Message recovery system [sec]
RP feed time [sec]
RP break time [sec]
Parameter: Explanation:
RP supply Yes: Reclaimed powder pump available
No: No reclaimed powder pump available
SAT: Speci c con guration for the SAT system
Operating mode Duration: Peristaltic pump operates continuously
Eco: Peristaltic pump works per cycle, that is, it works
during the "Feed time" adjustable time and subsequently
switches off for the "Break time" adjustable time (power
saving mode)
RP feed time [sec] Period in which the reclaimed powder pump is running
RP break time [sec] Time in which the reclaimed powder pump is at a standstill
Message recovery system [sec] A timer runs at the speci ed time after the initial feed
after cleaning. After this time expires, a note is displayed
on the screen to plug the recovery hose from the loss
position to the recovery position.
Home page
Cleaning
Settings
Alarm
Work-
station
FP
supply
Exhaust
system
DiagnosisSettings System
Cycle 3
RP
supply
Standard
Cycle 1 Cycle 4Cycle 2
Parameter: Explanation:
Cycle 1 – 4 Duration of the cycle 1 - 4
MP
operation
MP
operation
MP
cleaning
MP
cleaning