EasyManua.ls Logo

Water Ace R202A - User Manual

Default Icon
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
R300A
R301A
R302A
R314A
R3065A
R3067A
R3183A
R3207A
R3254A
R30610A
R200A
R201A
R202A
R203A
R214A
CONSUMER HOT-LINE: 1-800-942-3343
Monday–Friday 7 AM to 5 PM EST
www.waterace.com
OWNER’S MANUAL Pgs. 2-8
4" SUBMERSIBLE PUMPS, TWO AND THREE WIRE,
1/2 THRU 1-1/2 HP 60 HZ
NOTICE D’UTILISATION Pgs. 9-15
POMPE SUBMERSIBLE DE 4 PO À DEUX ET
TROIS FILS, DE 1/2 À 1-1/2 CV 60 HZ
MANUAL DEL USUARIO Pgs. 16-22
BOMBA SUMERGIBLES DE 4" DE DOS Y
TRES ALAMBRES, DE 1/2 A 1-1/2 HP, 60 HZ
WATER ACE PUMP COMPANY | 1101 MYERS PARKWAY | ASHLAND, OHIO 44805-1969 (USA ONLY)
WA843 (2/21/08)

Other manuals for Water Ace R202A

Questions and Answers

  • A
    Ashley AustinAug 9, 2025
    What to do if my Water Ace R202A Water Pump runs, but no water comes out?
    • R
      Richard MurrayAug 9, 2025
      If your Water Ace Water Pump is running but not delivering water, several issues could be the cause. It could be that the check valve is stuck—try shaking the pipe or raising and lowering the unit. If this doesn't work, remove the pump and clear any obstructions from the check valve. Other potential causes include a clogged intake (clean the screen or slots), worn impellers or diffuser (clean or replace them), a low well water level (lower the pump or install a low restrictor), or leaks (check all connections for airtightness). Also, low voltage to the pump can be a factor, so have the voltage checked by an electrician. The well might also be too deep for the pump.
  • E
    Eddie WhiteAug 15, 2025
    Why won't my Water Ace R202A start?
    • C
      Carrie JonesAug 15, 2025
      If your Water Ace Water Pump won't run, start by checking the fuse or circuit breaker. Also, inspect the piping for broken or open leads. If the fuse or breaker is fine, the pressure switch may be malfunctioning and need replacement. For 3-wire pumps, a control panel malfunction could also be the cause, so have an electrician check it.
  • F
    fnealAug 20, 2025
    How to fix a Water Ace R202A Water Pump that starts too often?
    • H
      Harold BradyAug 21, 2025
      If your Water Ace Water Pump starts too frequently, here are some things to check: * The pressure switch might be out of adjustment; follow the instructions on the inside of the switch cover to adjust it. * The check valve could be stuck open or seated improperly; try cleaning or replacing it. * If you have a bladder tank, release air from the tank's air charge valve. If water bubbles or spits out, the bladder has a hole. For galvanized tanks, check for a defective air-volume control. * There may be a leak in the system.
  • S
    Steven JohnsonAug 27, 2025
    What to do if my Water Ace Water Pump won't shut off?
    • K
      kfowlerAug 28, 2025
      If your Water Ace Water Pump does not shut off automatically, the pressure switch may be out of adjustment; follow the instructions on the inside of the switch cover. Alternatively, the pressure switch could be defective and need replacement. Other potential causes include a worn pump, a low well water level (lower the pump or install a flow restrictor). The well might also be too deep for the pump.
  • M
    Malik MartinSep 1, 2025
    Why does my Water Ace Water Pump blow fuses or trip breakers?
    • K
      Karen HarrisSep 2, 2025
      If your Water Ace Water Pump is blowing fuses, tripping breakers, or overloading, the fuses or breakers might be too small. Also, the wire size could be too small. A grounded motor or cable could also be the issue; have an electrician check it with an ohmmeter. Additionally, voltage that is too high or too low can cause these problems, so have it checked by an electrician. For 3-wire pumps, an incorrect control box could be the cause; compare the nameplate rating on the box to the pump HP.