CONSUMER HOT-LINE: 1-800-942-3343
Monday–Friday 7 AM to 5 PM EST
www.waterace.com
INSTALLATION MANUAL Pgs. 1–8
LAWN SPRINKLER PUMPS
POMPES POUR ARROSEURS DE PELOUSES
MANUEL D’INSTALLATION Pgs. 9–18
MANUAL DE INSTALACIÓN Pgs. 19–28
BOMBA DE ROCIADOR DE CÉSPED
WATER ACE PUMP COMPANY
|
1101 MYERS PARKWAY
|
ASHLAND, OHIO 44805-1969 (USA ONLY)
23833A308 (Rev. 11/7/05)
BAG #23834A002
R15L
1-1/2 HP
R10L
1 HP
R7L
3/4 HP
R25L
2-1/2 HP
R20L
2 HP

Questions and Answers

  • T
    Tracy CombsAug 9, 2025
    Why is my Water Ace R20L Water Pump not delivering rated capacity?
    • P
      Pamela MaynardAug 10, 2025
      If your Water Ace Water Pump isn't delivering its rated capacity, several factors could be at play. Start by checking that the suction pipe is submerged at least 3 feet below the water level and ensure the voltage of the pump matches the voltage of the power supply. Also, inspect the valve, suction piping, foot valve, or well point. Reduce the discharge system head, check for any leaks, and if the pump flow exceeds the well's capability, reduce the pump flow. Confirm all connections are airtight and that the suction pipe is 1-1/2".
  • S
    Stephen HahnAug 16, 2025
    What to do if Water Ace R20L motor overheats?
    • H
      Heather FarmerAug 17, 2025
      If your Water Ace Water Pump motor overheats and shuts off, make sure the motor voltage matches the power supply voltage. You may also want to check if the impeller is rubbing against the pump case. Refer to the Wire Size Guide on page 3.
  • R
    rebecca75Aug 25, 2025
    Why does my Water Ace Water Pump lose prime after starting?
    • E
      Emily SimpsonAug 25, 2025
      If your Water Ace Water Pump loses prime after starting, first make sure the suction pipe is at least 3 feet below the water level. Check for any leaks and ensure that the pump flow does not exceed the well's flow capability. Also, check that all connections are airtight.
  • S
    Steven DunnSep 1, 2025
    Why is my Water Ace R20L Water Pump so noisy?
    • C
      Charlotte RichmondSep 1, 2025
      If your Water Ace Water Pump vibrates or is noisy, ensure that the pump foundation is sufficient. Also, check for a bent shaft, worn motor bearing, or a clogged impeller. Note that the well depth should not exceed the pump's capability.

Summary

Important Instructions Before Installation

Warranty Void Conditions and Safety

Conditions that void warranty and critical safety precautions for pump installation.

Electrical and Grounding Requirements

Guidelines for proper electrical connections, grounding, and voltage matching.

Well Preparation and Piping

Procedures for well preparation, flushing, depth determination, and piping.

Specifications

Fuse, Breaker, and Wire Selection Guide

Guide for selecting appropriate fuses, circuit breakers, and wire sizes.

Pump Capacities and Performance

Table detailing pump capacities at various discharge pressures and lifts.

Pump Installation Procedures

Cased Well Installation Steps

Detailed step-by-step guide for installing pumps in cased wells.

Well Point Pump Installation

Instructions for installing pumps in well point systems.

Draining and Servicing for Winter

Procedures for draining and preparing the pump for winter or servicing.

Troubleshooting and Repair

Troubleshooting Checklist

Common pump problems and their possible causes and solutions.

Pump Disassembly and Repair Kits

Information on pump disassembly and available repair kits.

Limited Warranty Information

Water Ace R20L Specifications

General IconGeneral
ModelR20L
Inlet Size2 in
Voltage230/115 V
Phase1
Housing MaterialCast Iron
CategoryWater Pump

Related product manuals