EasyManua.ls Logo

Water Ace R100U - User Manual

Water Ace R100U
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
R100U
CONSUMER HOT-LINE: 1-800-942-3343
Monday–Friday 7 AM to 5 PM EST
www.waterace.com
WATER ACE PUMP COMPANY | 1101 MYERS PARKWAY | ASHLAND, OHIO 44805-1969 (USA ONLY)
253P7560 (1/18/06)
OWNER’S MANUAL Pgs. 2-7
UTILITY/TRANSFER PUMP
NOTICE D’UTILISATION Pgs. 8-13
POMPE DE TRANSFERT ET À USAGE GÉNÉRAL
MANUAL DEL USUARIO Pgs. 14-19
BOMBA PARA TODO USO/DE TRANSFERENCIA

Questions and Answers

  • E
    Erika MooreAug 5, 2025
    How to increase the water capacity of my Water Ace Water Pump?
    • A
      Alicia HoAug 5, 2025
      If your Water Ace Water Pump does not deliver water to full capacity, it could be because the water being pumped is lower than estimated, steel piping (if used) is corroded or limed causing excess friction, the piping is too small in size, or the pump is not being supplied with enough water. A deep well jet may be needed if the water being pumped is more than 25’ (7.6M) depth to water. Replace steel pipe with plastic pipe where possible, otherwise with new steel pipe. Re-pipe using the size of the suction and discharge ports on the pump. Add additional well points.
  • L
    lhernandezAug 15, 2025
    What to do if my Water Ace R100U Water Pump motor will not run?
    • R
      Richard CollinsAug 15, 2025
      If the motor of your Water Ace Water Pump won't run, the fuse may be blown, or the circuit breaker tripped. Disconnect the power and replace the fuse or reset the circuit breaker.
  • B
    burnettjosephNov 23, 2025
    Why does my Water Ace Water Pump motor run but no water is delivered?
    • K
      Kyle PrattNov 23, 2025
      If the motor of your Water Ace Water Pump runs but no water is delivered, it could be due to several reasons. During a new installation, the pump might not have picked up prime due to improper priming, air leaks, a leaking foot valve, or the pipe size being too small. If the pump has lost prime, it could be due to air leaks or the water level being below the suction pipe inlet. Other potential causes include a plugged impeller, a stuck foot valve, frozen pipes, or the foot valve and/or strainer being buried in sand or mud. Suggested solutions: For new installations: Re-prime according to instructions, check all connections on the suction line with soapy water or shaving cream, replace the foot valve, and re-pipe using the size of the suction and discharge ports on the pump. For installatio...

Summary

Owners Manual

Utility;Transfer Pump

Manual for the specific utility and transfer pump model, covering operation and maintenance.

Read and Follow Safety Instructions

General Safety

Electrical Safety

Specifications

Shallow Well Jet Pump Installations

Replacing an Old Pump

Boosting City Water Pressure

Piping

Priming and Operation

Preparing to Start the Pump

Troubleshooting

Limited Warranty

General Terms and Conditions

Outlines terms, conditions, exclusions, and limitations of the warranty.

Water Ace R100U Specifications

General IconGeneral
ModelR100U
CategoryWater Pump
TypeSubmersible Utility Pump
Phase1
Max Head25 ft
ConstructionThermoplastic
Max Flow Rate3000 GPH
Discharge Size1-1/4 inch
Maximum flow3000 GPH