What to do if Watson Marlow Pumps Water Pump fails to operate?
- MMrs. Victoria ReyesAug 1, 2025
First, check that the electrical supply is available at the pump. Also, verify the pump isn't stalled due to incorrect tubing installation.
What to do if Watson Marlow Pumps Water Pump fails to operate?
First, check that the electrical supply is available at the pump. Also, verify the pump isn't stalled due to incorrect tubing installation.
How often to change lubricant in Watson Marlow Pumps 501CC?
Under normal conditions, change the lubricant every 10,000 working hours or after 2 years. If the pump operates in extreme conditions (high air humidity, aggressive media, or large temperature variations), more frequent changes are needed. Combine a lubricant change with a thorough cleaning of the gear unit.
What to do if Watson Marlow Pumps Water Pump shows deviation from normal operating conditions?
Immediately inform maintenance personnel to prevent the problem from getting worse. If you're unsure, disconnect the pump right away.
How to replace V-belt on Watson Marlow Pumps Water Pump?
To replace the V-belt: 1. Unscrew the socket head screws and remove the cover with the entire speed control mechanism. 2. Remove the old V-belt. 3. Wrap the new V-belt around the open adjustable pulley and slip it over the spring-loaded pulley. 4. Replace the cover with the speed control mechanism and re-assemble. 5. When positioning the speed limiting lock nut (adjustable pulley closed), leave a 0.5-1.0mm gap on the adjustable pulley to avoid damage to the pulley and motor bearings. The V-belt should not touch the bottom of the adjustable pulley.
Which lubricating grease to use for Watson Marlow Pumps 501CC Water Pump?
Select the correct lubricating grease from the table in the back of this operating instruction.
How to lubricate bearing cage in Watson Marlow Pumps 501CC Water Pump?
Ensure the bearing cage is packed to about 1/3 with evenly distributed lubricating grease.
Why dust deposits on fan cover of Watson Marlow Pumps 501CC?
To prevent overheating, remove any dust from the fan cover.
Type | Peristaltic Pump |
---|---|
Motor Type | DC motor |
Hose Size | 1.6 mm ID |
Material | Stainless Steel |
Operating Temperature | 40 °C |
Control | Manual Speed Control |
Essential safety guidelines and warnings for operating and handling ATEX pumps, including hazard symbols.
Crucial pre-installation checks to ensure correct setup and compliance with ATEX requirements.
Guidelines for the physical installation of the pump, including lifting, mounting, and environmental considerations.
Practical advice on correct installation and usage to ensure optimal performance and safety.
A critical checklist for safely starting up the pump in explosive environments.
Procedures for maintaining the AC motor component of the pump.
Procedures for maintaining the gearbox component of the pump.
Procedures for maintaining the pneumatic motor component of the pump.
Procedures for maintaining the pumphead component of the pump.
Explanation of the ATEX marking symbols and their meanings for proper identification.
Detailed dimensions for the 501CC ATEX pump models, including various motor and gearbox configurations.
Detailed dimensions for the 621CC ATEX pump models, covering different motor and gearbox types.
Detailed dimensions for the 701CC ATEX pump models, including various motor and gearbox configurations.
Details on materials and finishes for Watson-Marlow manufactured components like pumpheads, adaptors, and baseplates.