EasyManua.ls Logo

Watson-Marlow MC100 - Page 24

Watson-Marlow MC100
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Users Manual
MC100
MC100 DeviceNet OM 1.01 EN.doc Version: 1.01 Page 24 of 36
Instance ID 8 Packed parameters from Instance ID 1-7
Attribute ID Description Type Value
1 Name Byte-String “Packed Parameters”
2 Data-type - double integer
3 Elements - 6
4 Access - Read/Write
5 Data values Double Integers Last Write values
6 Max. values Double Integers Max. values
7 Min. values Double Integers Min. values
Read
8 Default values Double Integers Default values
Write 5 Data values Double Integers >= Min and <= max values
Data structure for Instance 8:
Double Integer
1 Volume
2 Tube Speed
3 Acceleration Reverse
4 Density
5 Reserved
6 Reserved Reserved
Instance 9 Versions- and Alarm strings
Attribute ID Description Type Value
1 Name Byte-String “Versions / Alarms / Warnings”
2 Data-type -
4 (char)
String of (1-39) (char)
3 Elements - 39
4 Access - Read Only
5 MC100 Version char MC100 Version
6 Pump version Char Pump version
7 Alarm Type Char Alarm-string (Read at alarm)
Read
8 Warning Type char Warning-string (Read at warning)
Instance 10 Alarm number
Attribute ID Description Type Value
1 Name Byte-String “Alarm number”
2 Data-type - Integer
3 Elements - 1
4 Access - Read Only
5 Data value Integer
Alarm number
5
6 N.A. Integer
7 N.A. Integer
Read
8 N.A. Integer
5
Alarm – number is a reference to the Alarm list (Chapter 8).The text-string can also be read from Instance 9, Attribute
7.The number is also flashing on the 2-digit display [AL][number]