CHAPTER 23 CLICK 301 201
Startup
Allows you to configure active startup settings.
No Activity, the default, does not attempt to initiate a connection
under any circumstance.
Any Char attempts to connect when any character is received from the
serial port.
Active DTR accepts external connection requests only when the Mo-
dem Control In input is asserted.
Specific Char attempts to connect when it receives a specific start
character from the serial port. The default start character is a carriage
return. To change the character, see the Disconnect tab.
Manual Connect attempts to connect when directed by a command
string received from the serial port.
Autostart automatically connects to the remote IP address and remote
port specified when the firmware starts.
Modem Mode causes the unit to present a modem interface to the
attached serial device. It accepts AT-style modem commands and
handles the modem signals correctly.
Input Buer
Allows you to choose circumstances under which the input buer will
be flushed.
On Active clears the input buer when a connection is initiated from
the device to the network.
On Passive clears the input buer when a connection is initiated from
the network to the device.
At Disconn. clears the input buer when the network connection with
the device is disconnected.
Output Buer
Allows you to choose circumstances under which the output buer will
be flushed.
On Active clears the output buer when a connection is initiated from
the device to the network.
On Passive clears the output buer when a connection is initiated
from the network to the device.
At Disconn. clears the output buer when the network connection
with the device is disconnected.
Table 23.10 – Expert Driver Connect Tab
e Ethernet > Channel > Disconnect tab determines the conditions under which the unit
will cause a network connection to terminate (see Figure 23.13 and Table 23.11).