8.2. Description of the maintenance operations
Open the maintenance cover.
Check the intake area for the combustion air.
Remove larger objects that may clog the lter such as
leaves or rocks.
Unscrew the air lter cover (1).
Remove the wing nut on the air lter.
Remove the air lter insert (2).
ATTENTION! Danger of material damage from dirt particles.
Keep dirt or foreign objects from entering the intake
opening.
Blow out the air lter insert from inside to outside
with compressed air.
Check the air lter insert for damage and replace it if
necessary. See also Hatz instructions.
Tighten the air lter insert using the corresponding wing nut.
Screw on the air lter cover.
Close the maintenance cover.
Shut down the machine.
Remove the V-belt guard (1).
Check the V-belt (2) for cracks and wear.
Replace the V-belt if it shows signs of extensive wear
or other damage.
Fit the V-belt guard.
8.2.1. Clean the air lter
8.2.2. Check V-belt