Getting Started
Important Information about
NaturalGas & Gas Connections
What is Natural Gas?
Natural gas (NG) is a combustible, gaseous mixture
of simple hydrocarbon compounds, usually found in
deep underground reservoirs formed by porous rock.
It is a fossil fuel composed almost entirely of methane.
Natural gas is delivered by your local utility through an
underground pipeline system.
General Specifications
Three burner grills are designed to operate at 7" of
water column pressure (0.2526 psi).
Four burner grills are designed to operate at 4.5" of
water column pressure (0.16245 psi).
The quick-disconnect fitting can be installed
horizontally or pointing downward, but never pointing
upward. Installing it with the open end pointing upward
can result in water and debris collecting in the quick-
disconnect fitting.
The dust covers (plastic plugs supplied with your grill)
help keep the open ends of the quick-disconnect fitting
clean while disconnected.
Hose Requirements
The grill is equipped with a model specific hose that
was attached during the manufacturing process. This
specific hose must be used for proper performance.
If the hose becomes worn or damaged, contact the
Customer Service Representative in your area using
the contact information on our website.
Pressure Testing the Gas Supply
Disconnect the gas grill when the gas supply is being
tested at high pressures. This appliance and its
individual shuto valve must be disconnected from the
gas supply piping system during any pressure testing
of that system at test pressures in excess of 1/2 psig
(3.5 kPa).
Turn o the gas grill when the gas supply is being
tested at low pressures. This appliance must be
isolated from the gas supply piping system by closing
its individual manual shuto valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than 1/2psig (3.5 kPa).
Typical NG Grill Pipe Installation 310 • 315 • 325 • 330 • 335 Models
INSIDE HOUSE
Gas supply
Shuto
OUTSIDE HOUSE
Quick-disconnect
3/8" pipe nipple
Reducing coupling
1/2" pipe nipple
Locking shuto
Local codes may
require dierent
installations.
Flare fittings should
never be used.
Typical NG Grill Pipe Installation 410 • 415 • 430 • 435 Models
INSIDE HOUSE
Gas supply
Shuto
OUTSIDE HOUSE
Quick-disconnect
1/2" pipe nipple
Locking shuto
Local codes may
require dierent
installations.
Flare fittings should
never be used.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Weber Genesis II S-310 and is the answer not in the manual?

Weber Genesis II S-310 Specifications

General IconGeneral
Main Burners3
Total Cooking Area669 sq in
Primary Cooking Area513 sq in
Warming Rack Area156 sq in
Stainless Steel BurnersYes
Side Tables2
Dimensions - Lid Closed47" H x 59" W x 29" D
Grates MaterialPorcelain-enameled cast iron
Grill MaterialStainless Steel
Fuel TypePropane or Natural Gas
BTU Output39, 000 BTU
IgnitionElectronic Ignition System
Warranty10 years
Main Burners BTU39, 000 BTU
Wheels2