9. ELECTRICAL ENCLOSURE: The NEMA-4 control panel is not a food contact area and the use of
direct water washing (even low-pressure) is prohibited as it is not required and can be easily
cleaned by wiping down the enclosure with a damp cloth. It is advised to clean the exterior of the
Electrical Enclosure prior to examining the interior. Dislodge any particles or debris from the
electrical panel with compressed air, taking care not to damage any contacts.
The electrical enclosure includes 10 foot lead cables, meaning it can be mounted away
from the scale itself and away from water during cleaning. If this is not possible, always
cover the electrical enclosure during washing.
10. TOUCH SCREEN: The machine’s Touch Screen is IP-64 rated.
11. DRY COMPONENTS: Dry all components with a clean, dry cloth. No water spots should remain
on the machine. Leftover cleaning solution can cause damage to stainless steel surfaces.
12. REINSTALL COMPONENTS: Once cleaning is completed, reinstall all components.
13. TURN OFF AIR SUPPLY: All airflow to the machine should be shut off before normal operation.
Any air pressure within the machine will throw off the weights measured by the Load Cells.
14. END: The machine is now ready to be powered and run.