102
January, 2017
LOAD CELL CALIBRATION (THE MACHINE MUST BE POWERED WHEN PERFORMING THIS STEP)
Power the machine, then perform
a Load Cell Calibration
(see “Calibration” on page 74).
ENSURE THAT THE MACHINE HAS BEEN TURNED OFF, LOCKED OUT / TAGGED OUT BEFORE PERFORMING
MAINTENANCE ON PARTS. SOME CALIBRATIONS REQUIRE THE MACHINE TO BE POWERED, USE ALL DUE CAUTION
WHEN CALIBRATING THE MACHINE WHILE IT IS POWERED.
Ensure all Feed and Weigh
Buckets are mounted correctly
within their mounting brackets.
Ensure all Linear Vibrator Pans
are installed correctly and latched.
Ensure Center Cone is installed
correctly and tight, with a lock
washer on the mounting bolt.
Drain the Filter Regulator
completely.
Machine must be powered on
for this test, power it off and
Lock Out when the test is
complete:
Test the Emergency Stop button.