82
January, 2017
VIBRATOR SETTINGS
DELAY TO START (MS) – Indicates how much time the vibrator
will wait before starting.
ON TIME– Indicates how long the vibrator will be active for.
STRENGTH– Indicates how strong the vibrator will be.
FREQUENCY– Indicates what the frequency of the vibrator will be.
LOAD CELL SETTINGS
BIAS – Indicates the weight offset of the load cell.
SET TIME – Indicates how long to wait before trying to weigh the
weigher bucket.
NO. OF SAMPLES – Indicates the number of acquisitions to take
from the load cell before sending the weight
CYCLES TO TARE – Indicates the number of times the weigher
bucket will be used before zeroing.
MAX WEIGHT TARE – This field indicates how much weight can
accumulate in a weigh bucket before a zeroing is performed.
EXTERNAL INTERFACE
The external interface section is useful when trying to integrate an ancillary device to the PrimoCombi.
TRIGGER DUMPING– Pressing this button will simulate a dump signal.
TRIGGER DUMP READY– Pressing this button will simulate the dump ready signal.
TRIGGER FORCE DUMP– Pressing this button will simulate a forced dump signal.
DUMP REQUEST STATUS – This field will change from On to Off depending on the signal coming in
from the ancillary device.