i16 Manual Page 42 - Revision: 2-09-2023
o Failure to take this into consideration may cause the bladder to ineffectively fill
due to pressure drop with multiple units in line which mainly manifests itself as
the larger bladder tanks get closer to filling
o This will also result in burning through pre filters and using a lot of water that
will ultimately be just sent down the drain
Please see below for recommended air pressure that should be in the bladder depending on
size of the bladder.
5. Hot Water Dispense produces water that is not hot
Possible Reason
Solution
Overload Thermostat Tripped
Locate the Overload Thermostat mounted on the side of
the hot tank. Press the red button to manually reset the
thermostat and return the hot tank power circuit to normal
operation.
Hot Tank Power Switch is off
Locate the Hot Tank Power Switch on the
back of the machine and switch it on.