LIGHT
MEANING RESOLUTION
GREEN
(POWER INDICATOR)
RED
(OVERLOAD)
ON OFF Generator output is normal. No action needed.
ON Flashing continuously Generator is exceeding rated output. Reduce load on generator.
OFF Flashes 1x, repeating
every 3 sec
Voltage at alternator is too low. No elec-
trical output.
Check for loose connections. Call
1-800-232-1195 for assistance.
OFF Flashes 2x, repeating
every 3 sec
Engine speed is too low. No electrical
output.
Check carburetor and stepper motor.
Ensure Eco-Mode is OFF. Have genera-
tor serviced; call 1-800-232-1195 for
assistance.
OFF Flashes 3x, repeating
every 3 sec
Inverter temperature is too high. No
electrical output.
Turn generator off and let it cool down
fully (1 – 2 hours) before restarting.
OFF Flashes 5x, repeating
every 3 sec
Voltage at alternator is too high. No
electrical output.
Have generator serviced; call 1-800-
232-1195 for assistance.
OFF Flashes 6x, repeating
every 3 sec
Generator has exceeded rated output and
cut off power to protect itself. No electri-
cal output.
Turn OFF and disconnect loads. Press
RESET button on panel. Reduce load on
generator.
Table 3 - Power Cord Requirement Guide*NR = Not Recommended
Device Requirements Max. Cord Length (ft) by Wire Gauge
Amps Watts
(120V)
Watts (240V) #8 wire #10 wire #12 wire #14 wire #16 wire
2.5 300 600 NR NR NR 375 250
5 600 1200 NR NR 300 200 125
7.5 900 1800 NR 350 200 125 100
10 1200 2400 NR 250 150 100 50
15 1800 3600 NR 150 100 65 NR
20 2400 4800 175 125 75 50 NR
25 3000 6000 150 100 60 NR NR
30 3600 7200 125 65 NR NR NR
40 4800 9600 90 NR NR NR NR
WARNING! Generator should only be connected to electrical devices, either directly or with an extension
cord. NEVER CONNECT TO A BUILDING ELECTRICAL SYSTEM without a qualified electrician and connected to
a transfer switch as a separately derived system. Such connections must comply with local electrical laws and
codes. Failure to comply can create a back-feed, which may result in serious injury or death to utility workers.
NOTE: For power outages, permanently installed, stationary generators are better suited for providing backup
power to your home. Even a properly connected portable generator can become overloaded. This may result in
overheating or stressing the machine’s components, possibly leading to generator failure.
SOME NOTES ABOUT POWER CORDS
Refer to the following chart in determining the necessary gauge extension cord for each of your devices. Round up
to the higher amperage in the chart to maximize safety.