EasyManua.ls Logo

WerkMaster TITAN XT - Single-Phase to Three-Phase Adapter Cord; Pigtails; Stove and Dryer Adapter Plugs; Power Cord Minimum Requirements

WerkMaster TITAN XT
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATOR’S!MANUAL!!
+,-.!K!!
WerkMaster machines come in a variety of voltage and phase configurations.
The TITAN XT is typically configured to operate on 208230V three-phase
power. The TITAN XT is capable of operating on single-phase 208230V power
with the use of the included adapter cord.
COLOSSOS XT is capable of operating with 230V three-phase to 460V three-
phase power with the use of the adapter cord. Runs on 230V or 460V auto
synching.
!
!
Pigtails are plug ends with unfinished bare wire on one end for hooking up to
panels. Pigtails are used when connectivity is unknown, when connecting to the
power grid of an unfinished building that has no power receptacles, or when
operating certain generators. Many pigtails are available or can be made up by
an electrician.
!
When using the TITAN XT in a residential environment, source power may be
hard to find. The use of stove and dryer adapter cords make it easier to connect
to single-phase source power. The adapter cords are outfitted with a 30 A 250 V
single-phase twist-lock cord end for dryers and 40A 250V single-phase twist-lock
cord end for stoves. The single-phase to three-phase adapter is used to connect
the stove or dryer adapter cord to the TITAN XT only.
!
The following table lists the minimum requirements for power cords.
!
!
MODEL
DISTANCE
MINIMUM REQUIREMENT
TITAN XT
Up to 300 ft
Over 300 ft
Single-phase minimum gauge of 10/3
Three-phase minimum gauge of 10/4
Single-phase minimum gauge of 8/3
Three-phase minimum gauge of 8/4
COLOSSOS XT
230V
Up to 100 ft
Over 100 ft
Three-phase minimum gauge of 8/4
Three-phase minimum gauge of 8/4
COLOSSOS XT
380V/460V
Up to 300 ft
Over 300 ft
Three-phase minimum gauge of 10/4
Three-phase minimum gauge of 8/4
!
"@.!E2442G73-!5,_4.!47151!5@.!=737=;= !0.:;70.=.351!E20!-.3.0,5201>!
!
!
MODEL
MINIMUM REQUIREMENT (KW)
TITAN XT
11
COLOSSOS XT
25
!
!
!
!
!
Exercise extreme caution at all times when working with electrical power.
WerkMaster strongly recommends that only certified electricians be permitted to
work with electrical power sources within customers’ facility or on their job site.
!
!
!
!
!
Single-Phase to
Three-Phase Adapter Cord
Pigtails
Stove and Dryer
Adapter Plugs
Power Cord
Minimum Requirements
Generator
Minimum Requirements