Details components like slide staining carousels, reagent spray nozzles, dip tubes, and manual priming buttons.
Illustrates and describes rear panel components like exhaust vent, power switch, fuse door, volume control, drain port, and power entry module.
Describes the Aerospray AFB Stainer/Cytocentrifuge as a dual-purpose device for staining microbiological specimens.
Covers manufacturer and authorized representative details found on labels.
Explains how the device, accessories, and supplies are identified with model numbers and product numbers.
Explains that the IVD symbol signifies the diagnostic use as described in the intended purpose section.
Provides recommended storage temperatures and handling instructions for reagents to maintain quality and prevent issues.
Covers installing drain tube, power, reagent bottles, priming lines, and running a CLEAN cycle.
Guides on choosing stain modes (Carbol Fuchsin/Fluorescence) and setting stain intensity levels.
Details how to load slides into the carousel and place it into the stainer.
Instructions for entering the number of slides for partial loads to ensure accurate staining.
Details how to initiate a staining cycle, monitor progress, and recognize completion.
Explains the routine CLEAN cycle for maintaining nozzle performance and preventing clogging.
Describes the function of the STOP button to interrupt any cycle immediately.
Details how to perform spray pattern and slide pattern tests to check nozzle function and stain application uniformity.
Explains how to measure reagent volume and interpret test results for diagnosis.
Refers to maintenance tools and provides guidance on selecting instrument settings based on specimen thickness.
Refers users to the Operating Instructions section (6f) for the detailed procedure on how to use the instrument.
Directs users to specific tests (Spray Pattern, Volume, Interpreting Results) for internal quality control.
Directs users to specific tests for verifying instrument performance.
Details daily, weekly, and monthly maintenance procedures to ensure optimal instrument performance.
Provides guidance on diagnosing and resolving issues related to reagent delivery and spray nozzle performance.
Step-by-step instructions for disassembling and cleaning spray nozzles to resolve performance issues.
Detailed steps for correctly reassembling spray nozzles after cleaning.
General guidance on the proper disposal of fluids, recommending consultation of local regulations.
Instructions for correctly installing the drain tube to ensure proper liquid removal.
Details the procedure for connecting the instrument to a power source safely.
Provides the correct order for installing reagent bottles into the stainer.
Describes the purpose and contents of the Nozzle Maintenance Kit for optimal performance.
Step-by-step guide to prime reagent lines for optimal stainer performance.
Instructions for priming all reagent lines at once and for individual lines.
States device compliance with EMS directives and safety precautions for use.
Outlines the proper disposal method for the equipment according to WEEE Directive.