4 Startup and Basic Operation Operator Manual for Gasoline Generators
page 20
CAUTION: When starting the generator, it is recommended that all AC loads, especially large motors, be switched OFF
until the engine has come up to speed and, in cold climates, starts to warm up. This precaution will prevent damage
caused by unanticipated operation of the AC machinery and will prevent a cold engine from stalling.
Figure 16: Engine Oil and Coolant System Components
4.11
Checklist: Daily Startup
Follow this check list each day before starting your generator.
Visually inspect the generator for fuel, oil, water leaks or loose parts.
Check the oil level on the dipstick.
Check the coolant level in the coolant recovery tank.
Check your fuel supply.
Check drive belts for proper tension.
Check for abnormal noise such as knocking, vibration and blow-back sounds.
Inspect the exhaust system.
Record the hour meter reading in your log to determine if any maintenance is required.
See 5.1 Maintenance Schedule.
NOTE: Some unstable running may occur when the engine is cold. This condition should lessen as normal operating
temperature is reached and loads are applied.