EasyManua.ls Logo

Westomatic Easy 6000 - 8.2.3 MACHINE PARAMETER SETTINGS CONTINUED

Westomatic Easy 6000
41 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EASY 6000 Issue 02 23
FAS INTERNATIONAL S.p.A. Via Lago di Vico, 60 SCHIO (VI) tel. +39 0445 502011 fax +39 0445 502010 - e-mail: info@fas.it
E
N
G
L
I
S
H
Command 64 Sets the message display language:
This command controls the language in which the messages are displayed. Value 0 corresponds to Italian,
value 1 to English, value 2 to French, value 3 to German, value 4 to Dutch, value 5 to Swedish, value 6 to
Finnish and value 7 to Spanish 8 to Portuguese 9 to Danish 10 to Norwegian.
Command 65 Displaying optional messages:
This is for modifying the message displayed by the machine at the moment in which the selection is made.
When the command is set to 1, the machine will display the message, "enter the card price xx", when the
payment system is a credit card.
Commands 66-67 Internal temperature and evaporator temperature display:
The value set at these commands determines the information shown on the second line of the display (see
table). As default, the clock is displayed.
Command 67
Displayed value
0
Displays clock
0
Displays internal temperature *
1
Displays internal temperature + evaporator temperature
1
Displays clock + internal temperature
Command 68 Setting displayed currency description :
The command allows the operator to set the desired currency. 4 characters are available and they are
entered using the same method as described for Command 95.
Command 69 Chooses functioning mode of the coin mechanism:
This command chooses the type and mode of functioning of the coin mechanism. The parameter can
assume the following values:
0 System EXECUTIVE with prices controlled in the machine (see relevant paragraph).
1 System EXECUTIVE in PRICE HOLDING mode (i.e. prices programmed in the coin mechanism). In this
case, the prices programmed at command 03 and those programmed in the coin mechanism must be the
same (see relevant paragraph). Alternatively you can set the Price-Display parameter. If enabled, the
vending machine will utilize exclusively the information on the price value deriving from the payment system,
that is, it will not be necessary to fill in the price tables (Commands 03 and 04); simply set only Command 05
(see relevant paragraph).
4 System BDV 001 (see paragraph using the coin mechanism BDV)
5 Payment system MDB (see paragraph on using the MDB payment system).