Command 27 Setting the signal for payment system out of order:
If the command is set at 1, when the connection with the MBD payment system is interrupted the vending
machine goes out of order and the message appears on the display; if the command is set at 0 (zero), the
option is disabled. The default setting is 0.
Command 28 Select change giving tube content counter:
This command allows the user to select whether to use the counters corresponding to the content of the coin
mechanism change giving tube or use only the counters inside the machine. If the command is set at 1 at
each power-up the counters inside the machine which correspond to the content of the change giving tubes
are updated with the values transmitted by the coin mechanism. If, on the other hand, the command is set at
0 the values transmitted by the coin mechanism are ignored.
Command 29 Cashless credit cannot be displayed:
This command allows the user to prevent or enable display of credit from the MDB cashless device (key or
card reader). If the command is set at 1 the credit corresponding to the cashless device is not displayed,
whereas if the command is set at 0 the machine also displays the credit available on the cashless device.
Command 30 Purchase obligation before return:
By setting this command to 1 the customer is obliged to purchase before receiving back the return. This is to
avoid to use the coin mechanism as a coin-changer. If the purchase fails to happen, the return will be given
out.
Command 31 Setting max key or cash credit accepted:
The max credit accepted by the coin mechanism by either key/card or cash is set, and if this amount is
exceeded acceptance of further coins or notes is blocked.
Next follows a request for the maximum return option, that is the maximum quantity of coins that can be
returned; default value 1000, max value 9000.
Command 32 Minimum coin level in the tubes:
This is the number of coins for each coin box mechanism which must remain in each tube in order to
guarantee the correct function of the coin delivery system. (Consult the manual of the coin box mechanism
for instructions on setting the correct value of this parameter). If a different value is associated to each tube,
the maximum value set must be between those indicated. The setting of this parameter is fundamental for
ensuring the correct coin management by the vending machine.
N.B. The inventory of the tubes, command 38, stops when the contents of each tube reaches the value set at
command 32. To empty the tubes completely, use the delivery pushbuttons of the coin box mechanism.