SERVICE
Whirlpool Europe 200 380 21 12.07.2002 / Page 3
Customer Service 8545 856 01600 Doc. No: 4812 718 18097
Technical data
Motor
Spray pump motor
Voltage 220/ 240 V
Power consumption 150 W
HI ~ 45 Ω
HA ~ 54 Ω
Capacitor 6 µ F
Drain pump motor
Voltage 220/ 240 V
Frequency 50 Hz
Power consumption 38 W
Resistance ~ 146 Ω
Heating
1 Element flow through system
Voltage 220/ 230 V
Power consumption 2.05 kW
Resistance 24.5 Ω
Heating speed ~ 2.0 ˚C/min
Temperature on surface ~ 115 ˚C
Safety thermostat
self reset
(Temperature of water) ~ 85 ˚C
Fuse 206 ˚C
Double electric inlet valve ELTEK
Voltage 220/ 240 V
Frequency 50/ 60 Hz
Resistance ~ 2.0 kΩ
Safty system against water-leakage?
Aquastop + floater switch
(Floater switches of the inlet valve and on the drain
pump)
Regeneration valve
Voltage 220-240 V
Power consumption 6 W
Resistance ~ 3.75 kΩ
NTC
23 ˚C ~ 14 kΩ
Water measuring
Remove the coases sieve, put into the sump a
meassuring meter, look the height of the water
level
Working level 110 mm
Safety level 125 mm
Coil of dispenser
Voltage 220/ 240 V
Frequency 50/ 60 Hz
Resistance ~ 1.2 kΩ
Regeneration and Volumes
Salt container volume 1.5 kg
Volume for regeneration 320 cm
3
Steps to set
the water softening system 5
Default Water hardness setting 3
Number of washing cycles
with 1.5 kg salt 20
Position of
selector setting
German degrees
˚dH
French degrees
˚fH
Setting N.1 NO SALT 0 - 4 0 - 7
Setting N. 1 5 - 9 8 - 15
Setting N. 2 10 - 17 16 - 30
Setting N. 3 18 - 26 31 - 45
Setting N. 4 27 - 35 46 - 60
Setting N. 5 36 - 47 61 - 80