OPERATION INSTRUCTIONS
BEFORE USING YOUR APPLIANCE
Remove the exterior and interior packing
Before connecting the appliance to the power source, let it stand upright for approximately 4 hours. This will reduce
the possibility of a malfunction in the cooling system from handling during transportation
SWITCHING ON/OFF THE AIR CONDITIONER
The appliance can be switched ON or OFF by pressing the POWER button on the control panel or the ON/OFF but-
ton on the remote control
COOLING MODE
In this mode, the air conditioner cools and dehumidifies the room. To activate this function mode, press the Mode
Control until the Cooling indicator light comes on. When the cooling mode is set, the compressor will start in ap-
proximately 3 minutes. In cooling mode, hot air is exhausted from the outdoor exhaust port and the exhaust hose
must be connected to exhaust out the hot air.
The temperature setting range of this air conditioner is from 61°F / 16°C to 89°F / 32°C. To set the temperature,
press the or buttons. This air conditioner has a 5°F temperature cushion which if the set temperature is within
5°F of the ambient temperature, the unit runs on fan only mode. This saves energy and prolongs the life of the com-
pressor of the air conditioner.
To set the fan speed, press the FAN button. In cooling mode, the difference in noise level between the 3 fan speeds
is not very noticeable when the compressor is on. Try setting the unit to Fan only mode, you should be able to hear
the difference between high and low fan speed settings.
DEHUMIDIFYING ONLY MODE
In this mode, the air conditioner only dehumidifies the room, the compressor will activate intermittently depending on
the ambient temperature and the fan speed is set to LOW. To activate this function mode, press the Mode Control
until the Dehumidifying indicator light comes on. Please note that when switching function mode, there will be an
approximately 3 minute transition time. In dehumidifying mode, do not connect the exhaust hose and let the warm air
return to the room. If room temperature is higher than 77°F, the fan speed can be adjusted. If room temperature is
lower than 77°F, the fan speed is set at Low.
NOTE: When using the Dehumidifying mode, the exhaust hose should not be vented to the outside. If the warm air is
exhausted to the outside, cooling may occur. Additionally, you must manually drain the water from the unit.
FAN ONLY MODE
In this mode, only the fan of the air conditioner runs and circulates the air in the room. To activate this function mode,
press the MODE button until the Fan indicator light comes on. In this function mode, the temperature cannot be
set. Subsequently, set the desired fan speed by pressing the Fan button. Fan Only mode does not require the use of
the exhaust hose.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Whynter ARC-101CW and is the answer not in the manual?

Whynter ARC-101CW Specifications

General IconGeneral
Typeportable
Colorwhite
Operating Area Size300 square feet
Cooling Settings1
Seasonally Adjusted Cooling Capacity5214.9 british thermal units
Heaterno
Fan Airflow Rate145 cubic feet per minute
Filtercarbon
Hosesingle
Remote Controlyes
Timeryes
Sleeping Modeno
Current9.4 amperes