EasyManuals Logo

Whynter ARC-101CW User Manual

Whynter ARC-101CW
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
17
TROUBLESHOOTING
Problem Possible Causes Solutions
The unit has worked for a long
time, but the room is not cold
enough
Windows or doors are open
There are too many people in the
room
There is direct sunshine into the
room
The room is a kitchen or with many
heat-producing appliances
There is a server in the room
The room is too large
Close all windows and doors
You may need additional cooling or
another air conditioner
Close curtains or blinds and try to min-
imize the amount of direct sunlight into
the room
You may need additional cooling or
another air conditioner
The unit is very noisy The unit is not level
The surface underneath the unit is
uneven
Low power voltage
Make sure the unit is on hard, level
and stable surface
Move the unit to a location with a level
and hard floor
Make sure the wall outlet and support
the required power consumption of the
air conditioner and do not use an ex-
tension cord
The unit leaks water The unit is tilted or not leveled
The water tank is full
Make use the unit is leveled
Drain water from the drain plug at the
back of the air conditioner
Fan speed cannot be changed Fan speed differences are not very
noticeable
The fan speed difference is not very
noticeable when the compressor is on.
Try setting the unit to Fan only mode,
you should be able to hear the differ-
ence between high and low fan speed
settings.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Whynter ARC-101CW and is the answer not in the manual?

Whynter ARC-101CW Specifications

General IconGeneral
Typeportable
Colorwhite
Operating Area Size300 square feet
Cooling Settings1
Seasonally Adjusted Cooling Capacity5214.9 british thermal units
Heaterno
Fan Airflow Rate145 cubic feet per minute
Filtercarbon
Hosesingle
Remote Controlyes
Timeryes
Sleeping Modeno
Current9.4 amperes

Related product manuals