26
05 HMI BAR MOUNT
5.4 Charge Level & Errors
Error Code Information Table:
Code Condition User Handling Retailer Handling
11 Controller exceeds temperature over
protection setting
Wait until temperature back to normal Wait until temperature back to normal
12 Motor temperature over protection
setting
- Please check if motor cable connection is ne
- Wait until temperature back to normal
- Please contact your nearest service shop
- Please check if motor cable connection is ne
- Please check NTC status
13 Battery voltage under protection setting Please recharge the battery - Please recharge the battery
- Please check battery status
14 Regeneration does not work Please contact your nearest service shop Please return to Whyte/Kynamic Service Center
if error continues
15 Turn on system when bike is moving Stop the bike completely and hold up for 2
seconds
Stop the bike completely and hold up for 2 seconds
17 BMS communication lost Please contact your nearest service shop Please check connection between battery and
controller
18 Controller detect BMS error Please contact your nearest service shop None
19 Battery SOC is higher than setting and
regeneration is activated
Please contact your nearest service shop
30 HMI Lost Communication - Please check connection between HMI and
system
- Please contact your nearest service shop if this
error persists
- Please check connection between HMI and system
- Please check controller status
- please return HMI and/or controller to
Whyte/Kynamic service centre if error persists
31 FW is damaged or lost in the controller - Please repeat update rmware for a few times
- Please return the controller to the service shop
- Please repeat update rmware for a few times
- Please return the controller to Whyte/Kynamic
Service Center