24 WIKA operating instructions pressure transmitter, model S-20
14043170.01 04/2013 GB/D/F/E
GB
10. Dismounting, return and disposal
10.2 Return
WARNING!
Absolutely observe when shipping the pressure transmitter:
All pressure transmitters delivered to WIKA must be free from any kind of hazardous substances (acids,
bases, solutions, etc.).
When returning the instrument, use the original packaging or a suitable transport package.
Label the shipment as transport of a highly-sensitive measuring instrument in order to avoid any damage.
Information on returns can be found under the heading "Service" on our local website.
10.3 Disposal
Incorrect disposal can put the environment at risk.
Dispose of instrument components and packaging materials in an environmentally compatible way and in accordance
with the country-specic waste disposal regulations.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WIKA S-20 and is the answer not in the manual?

WIKA S-20 Specifications

General IconGeneral
Accuracy≤ 0.5 % of span
Output Signal4 ... 20 mA, 0 ... 10 V, 0.5 ... 4.5 V ratiometric
Process ConnectionG ¼ NPT, ¼ NPT
Electrical ConnectionM12 x 1
Materials (wetted)Stainless steel
Temperature Range-40 ... +125 °C
Ingress ProtectionIP65
Power Supply10 ... 30 V DC