26
Part Number 550-142-785/0812
10 Operating instructions
FOR YOUR SAFETY READ BEFORE OPERATING
Ifyoudonotfollowtheseinstructionsexactly,areorexplosionmayresultcaus-
ingpropertydamage,personalinjuryorlossoflife.
A. This appliance is equipped with an ignition
device which automatically lights the pilot. Do
not try to light the pilot by hand.
B. Before OPERATING, smell all around the
applianceareaforgas.Besuretosmellnext
to the floor because some gas is heavier than
air and will settle on the floor. See below.
C. Useonlyyourhandtodepressormovetheselectorarm.Neverusetools.
Iftheselectorarmwillnotdepressormovebyhand,don’ttrytorepairit,
callaqualiedservicetechnician.Forceorattemptedrepairmayresultin
areorexplosion.
D. Donotusethisapplianceifanyparthasbeenunderwater.Immediately
callaqualiedservicetechniciantoinspecttheapplianceandtoreplace
anypartofthecontrolsystemandanygascontrol,whichhasbeenunder
water.
• Donottrytolightanyappliance.
• Donottouchanyelectricswitch;donotuseanyphonein
your building.
• Immediatelycallyourgassupplierfromaneighbor’sphone.
Followthegassupplier’sinstructions.
• Ifyoucannotreachyourgassupplier,calltheredepart-
ment.
WHAT TO DO IF YOU SMELL GAS
1. STOP!Readthesafetyinformationaboveonthislabel.
2. Set the thermostat to lowest setting.
3. Turnoffallelectricalpowertotheappliance.
4. Removejacketfrontpanel.
5. Thisapplianceisequippedwithanignitiondevicewhichautomaticallylightstheburner.
Do not try to light the burner by hand.
6. Turn Gas control knobclockwise
to OFF.
7. Waitve(5)minutestoclearoutanygas.Thensmellforgas,includingneartheoor.
Ifyousmellgas,STOP!Follow“B”inthesafetyinformationabove.Ifyoudon’tsmell
gas,gotothenextstep.
8. Turn Gas control knobcounterclockwise
to ON.
9. Turn on all electric power to the appliance.
10. Set thermostat to desired setting.
11.Iftheappliancewillnotoperate,followtheinstructions“TO TURN OFF GAS TO AP-
PLIANCE” below and call your service technician or gas supplier.
12.Replacejacketfrontpanel.
OPERATING INSTRUCTIONS
TO TURN OFF GAS TO THE APPLIANCE
1. Set the thermostat to lowest setting.
2. Turnoffallelectricpowertotheapplianceifserviceisto
beperformed.
3. Removejacketfrontpanel.
4. Turn Gas control knobclockwise
to OFF. Do not
force.
5. Replacejacketfrontpanel.
GWI