EasyManua.ls Logo

Wilo Atmos PICO - Fault signals

Wilo Atmos PICO
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18 Wilo SE 07/2019
en
10.1 Fault signals
The fault signal LED indicates a fault.
The pump switches off (depending on the fault) and
attempts a cyclical restart.
If the fault cannot be remedied, contact a specialist
technician or Wilo customer service.
LED Faults Causes Remedy
Lights
up red
Blocking Rotor blocked Activate manual
restart or contact
customer service
Contacting/
winding
Winding defective
Flashes
red
Under/overvoltage Power supply too
low/high on mains
side
Check mains
voltage and
operating
conditions, and
request customer
service
Excessive
module
temperature
Module interior too
warm
Short-circuit Motor current too
high
Flashes
red/
green
Generator
operation
Water is flowing
through the pump
hydraulics, but there
is no mains voltage at
the pump
Check the mains
voltage, water
quantity/pressure
and the ambient
conditions
Dry run Air in the pump
Overload Sluggish motor,
pump is operated
outside of its specifi-
cations (e.g. high
module tempera-
ture). The speed is
lower than during
normal operation

Related product manuals