54 Installation and operating instructions • Wilo-Control SC2.0-Booster • Ed.01/2023-09
3~400V, 2-pole, direct starting
Power in kW System impedance in ohm Connections/h
2.2 0.257 12
2.2 0.212 18
2.2 0.186 24
2.2 0.167 30
3.0 0.204 6
3.0 0.148 12
3.0 0.122 18
3.0 0.107 24
4.0 0.130 6
4.0 0.094 12
4.0 0.077 18
5.5 0.115 6
5.5 0.083 12
5.5 0.069 18
7.5 0.059 6
7.5 0.042 12
9.0–11.0 0.037 6
9.0–11.0 0.027 12
15.0 0.024 6
15.0 0.017 12
3~400V, 2-pole, star-delta starting
Power in kW System impedance in ohm Connections/h
5.5 0.252 18
5.5 0.220 24
5.5 0.198 30
7.5 0.217 6
7.5 0.157 12
7.5 0.130 18
7.5 0.113 24
9.0–11.0 0.136 6
9.0–11.0 0.098 12
9.0–11.0 0.081 18
9.0–11.0 0.071 24
15.0 0.087 6
15.0 0.063 12
15.0 0.052 18
15.0 0.045 24
18.5 0.059 6
18.5 0.043 12
18.5 0.035 18
22.0 0.046 6
22.0 0.033 12
22.0 0.027 18