Ceram C0 data sheet
E-2 WILO EMU 3.0
Resistance
Total layer thickness: at least 400µm
Key: 1 = resistant; 2 = resistant for 40 days; 3 = resistant against overflow, immediate cleaning rec-
ommended
Pumped fluid Temperature Resistance rating
Waste water, alkaline (pH 11) +20°C 1
Waste water, alkaline (pH 11) +40°C 1
Waste water, slightly acidic (pH 6) +20°C 1
Waste water, slightly acidic (pH 6) +40°C 1
Waste water, very acidic (pH 1) +20°C 2
Waste water, very acidic (pH 1) +40°C 3
Ammonium hydroxide (5%) +40°C 3
Decanol (fatty alcohol) +20°C 1
Decanol (fatty alcohol) +50°C 1
Ethanol (40%) +20°C 1
Ethanol (96%) +20°C 3
Ethylene glycol +20°C 1
Heating oil / diesel +20°C 1
Compressor oil +20°C 1
Methyl ethyl ketone (MEK) +20°C 3
Sodium hydroxide solution (5%) +20°C 1
Sodium hydroxide solution (5%) +50°C 2
Sodium chloride solution (10%) +20°C 1
Hydrochloric acid (5%) +20°C 2
Hydrochloric acid (10%) +20°C 2
Hydrochloric acid (20%) +20°C 3
Sulfuric acid (10%) +20°C 2
Sulfuric acid (20%) +20°C 3
Nitric acid (5%) +20°C 3
Tolue ne +20°C 2
Water (cooling/industrial water) +50°C 1
Xylene +20°C 1
Table E-2: Resistance