Marine Installation Manual 2021-08 4-67
4 Ancillary Systems
4.6 Fuel oil system
X72DF
For changing over between heavy fuel oil and marine diesel oil (MDO/MGO)
and vice versa, as well as for operation on distillate fuel, refer to the separate
Concept Guidance (DG 9723), which is provided on the WinGD webpage
under the following link:
Concept Guidance Distillate Fuels
Figure 4-40 Mixing unit
Type Cylindrical steel fabricated pressure vessel as shown in
Figure 4-40
Capacity Refer to GTD.
Dimensions See MIDS.
Service pressure 10bar
Test pressure According to classification society
Working temperature Up to 150 °C
2
SM-0068
1
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Outlet
Inlet, return pipe
Inlet from feed pump
Vent
Drain
Heating coil
Insulation
Mounting brackets