Safety notes
3
¾ These arrows indicate procedural instructions
D This symbol indicates the results of your actions
−
This symbol denotes lists
X This symbol refers to a chapter with further information
3 Safety notes
Comply with the safety notes so that installation can be performed safely.
Danger
DANGER! Risk of fatal injury due to live components.
Disconnect the machine from the mains and check that machine is de-energised.
− Installation must be performed by a service technician trained by Winterhalter.
− The machine is still live unless the on-site mains disconnector or the built-in mains disconnector is
switched off.
− Installation may only be performed by a service technician trained and authorised by Winterhalter.
− When using chemicals, adhere to the safety notes and recommended dosages printed on the packaging.
− Wear protective clothing, protective gloves and protective goggles when handling chemicals.
4 Requirements
The machine must have been connected to the following in accordance with the installation instructions:
− Electrical mains
− Water supply and drainage
5 Checking the electrical installation
Danger
DANGER! Risk of fatal injury due to live components.
Disconnect the machine from the mains and check that machine is de-energised.
¾ Obtain access to the electric installation compartment behind the front cladding.
¾ Check the following:
− Has the electrical installation been performed according to the information on the rating plate (mains volt-
age, fusing, feeder cross section)?
− Have the terminals of the mains connection cable been firmly tightened?
− Has a mains disconnector been installed in the building?
− Has a residual-current circuit breaker been installed in the building?
− Has the machine been connected to the equipotential bonding system?
¾ Tighten the screw on the contactors.