EasyManua.ls Logo

WisyCom MTP60 - MTP60 Microphone Mode Configuration; MTP60 Tone Squelch Configuration; MTP60 PTT (Push-to-Talk) Functionality; MTP60 Limiter and Distortion Control

WisyCom MTP60
17 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MTP60 mul-band bodypack transmier
9
no filter)
Mic Mode menu set the audio mic connection.
Following Mic mode can be setup:
2W (2 wires): (PTT is possible) for external audio input
2W+B (2 wires + bias): (PTT is possible) for most 2 wires MIC
3W (3 wires): (no PTT) for most 3 wires MIC
2W&P (2 wires & Phantom): to connect a wired mic thru a 48V adapter (PHA60/PHA48)
2W+B&P (2 wires+bias & Phantom): Allow to connect a ‘2 wires + bias’ MIC or a ‘2 wires &
phantom’ MIC (with PHA60/PHA48 accessory)
Instrument: high impedence input
Tone menu set to normal to enable Wiisycom Tone Squelch (@33kHz). The tone is used by the
receiver to to send to recognized Wisycom transmitter is active. In the same tone the transmitter
sends to the receiver the battery lifetime, the compander and the ch. modulation too. Set tone
to No Data if you don’t want to send these additional information.
PTT menu allows to configure the behaviour of PTT accessory when it is pushed.
If PTT is set to Mute, the audio is muted when the Push to Talk button is pushed.
If PTT is set to ON, Wisycom receiver is able to do an audio routing according to Tone squelch
matrix set on the receiver (see receiver user manual for more details).
Limiter to enable or disable the limiter function. Whem limiter is anable and the audio input
level is too high (level on the audio bar arrives to the peak) the transmitter adapt acutomatically
the audio level to avoid distorsion.
Cal. tone to activate the calibration tone.
The CALIBRATION TONE function generates a tone at specific frequecies (400Hz or 1000 Hz) at
-20dB level on the audio input.
Calibration tone Example – DPA 40xx would typically use 2W+B for 2 wire plus bias giving the 5V required for the
mic. A good starting place for this could be -6dB for starting with an interview. This setting allows for a range from -40dB
to +26dB
Example – Instrument typically for use with instruments that have a higher output level. Suggested starting gain is -23dB.