Care and Maintenance
26
25
Care and Maintenance
Operation
Commands
Function
Description
Remarks
[Program
Password] + [#]
Enter settings
Default password: 8888
[*] + [#]
Enter settings
[20]+[1~8]
+ [#]
Coding of Remote
Controller
Max 8 remote controllers
[23] +[01~99]
+ [#]
Coding of Defense
Zones
Defense Zones Number: 01~99
[24] +[01~99]
+ [#]
Delete Defense
Zones
Defense Zones Number: 01~99
[30]+[password]
+ [#]
Change Operation
Password
Default: 1234
[31]+[password]
+ [#]
Change Program
Password
Default: 8888
[32] + [AA] + [BB]
+ [CC] + [DD] +
[EE] + [FF] + [#]
System Time Setting
[AA]: year [BB]: month[CC]: date
[DD]: hour [EE]: minute [FF]: second
[33~35] + [AA] +
[BB] + [#]
Timely Arm
3 groups of auto arm time
[AA]: hour [BB]: minute
[36~38] + [AA] +
[BB] + [#]
Timely Disarm
3 groups of auto disarm time
[AA]: hour [BB]: minute
[39] + [0/1] + [#]
Timing Control: turn
on/ off the function of
timely arm/disarm
0: OFF 1: ON
[41] + [0/1] + [#]
Wireless
Transmission Control
0: OFF 1: ON
[42] + [01~99]
+ [#]
Wireless Siren
Coding Encryption
Siren coding number: 01~99
[44] + [01~99]
+ [#]
Out Arm Delay
Time Setting
Default: 60seconds
[45] + [01~99]
+ [#]
Alarm Delay
Time Setting
Default: no delay
[51]~[56] + Phone
number + [#]
Alarm Number
Setting
6 groups of alarming user number
[51]~[56] + [#]
Delete Phone Number
[57]~[59] + Phone
number + [#]
SMS Receiving
Number Setting
3 groups of SMS receiving number
[57]~[59] + [#]
Delete SMS Receiving
Number
[60] + [AA] + [B] +
[C] + [D] + [#]
Defense Zone
Programming
AA: Defense zone number: [01~99]
B: Defense zone type: [1]real-time;
[2] 40 seconds delay; [3]24 hours;
[4] bypass
C: Defense zone location: [1]SOS
Alarm; [2] Fire Alarm; [3]Gas Leak
Alarm; [4]Door Alarm; [5]Hall Alarm;
[6]Window Alarm; [7]Balcony Alarm;
[8]Boundary Alarm
D: Siren ON/OFF
[0] OFF, [1] ON
[61] + [01~12] +
[0/1] + [#]
Home Arm Defense
Zone Setting
Defense zone number: 01~12;
[0] Home arm but not alarm;
[1] Home arm and alarm
[70] + [1] + [#]
Voice Recording
10 seconds
[75] + [0/1] + [#]
Siren Setting [0]: off (default); [1]: on
[76] + [0/1] + [#]
Siren Setting in
“Emergency Help” mode
[0]: off (default); [1]: on
[77] + [1/0] + [#]
SMS Notification for
Arm/ Disarm
[81] + [#]
GSM Signal Checking
Intensity: 07-31 (if it’s less than 07,
you should change place.)
[83] + [0/1] + [#]
Arm/ Disarm
Voice Prompt
[0]: off; [1]: on (default)
[84] + [0/1] + [#]
Voice Prompt for
All Settings
[0]: off; [1]: on (default)
[88] + [#]
IMEI Checking
[*] + [0] + [#]
Alarming Record
Checking
Press 2: upturn
Press 8: downturn