EasyManua.ls Logo

Wood-mizer Edger Multi-Rip - DC Electromagnetic Brake; Design and Principle of Operation

Wood-mizer Edger Multi-Rip
87 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DC Electromagnetic Brake
Design and Principle of Operation
8
8-1 EAdoc091010 DC Electromagnetic Brake
SECTION 8 DC ELECTROMAGNETIC BRAKE
1 - Electromagnet,
2 - Armature complete with brake linings,
3 - Fan,
4 - Retaining bolt
5 - Central spring,
6 - Special washer,
7 - Set screw,
8 - Self-locking nut,
9 - Sealing ring,
10 - Output cable.
8.1 Design and principle of operation
The DC electromagnetic brake type H consists of 3 main subassemblies:
- electromagnet (1),
- armature complete (2)
- cast iron fan (3).
E
lectromagnet (1) energised: The DC voltage from the motor applied via the rectifying circuit
causes the attraction of the armature (2) releasing the brake and thus the fan (3) is free to rotate.
Electromagnet (1) de-energised: The electromagnet stops to attract the armature (2) and spring
presses the armature with brake linings (2) against the fan and the brake is thus applied.