SETWORKS OPERATION
Start-up settings of the controller
4
4-2 EGdoc090110 SETWORKS OPERATION
Descriptions of the control panel buttons:
A, B, C, D, E - blades width memory buttons.
SET ABCDE - Sets the blades width value to each memory button.
Save - Saves parameters determined by operator.
Blades width manual setting buttons (in/out).
ENTER – enters the value to the memory
Auto Mode – Adjustment of the setworks automatic calibration parameters. Used for initial calibration
and re-calibration if dimensional error occur.
Set Real Size - Sets the real distance between saw heads. Should be set when “Check real size”
indicator lamp blinks.
4.2 Start-up settings of the controller
1. Setting the input divider (entered only once, at the first start-up)
Switch on the controller by turning the main switch to ON position.
When the text “TBS-01” appears on the display, press and hold until the divider value
appears on the lower right display.
Enter the correct value of the divider (for Edger the divider value should be 5).
A
SET
ABCDE
SAVE
ENTER
AUTO
CAL.
SET
REAL SIZE
AUTO
CAL.