INTRODUCTION
Machine Description
INTRODUCTION doc052521 1-5
1
1 x 0.1 mm height (per cutter)
These spacer rings are necessary to set the required height.
CHIP EXTRACTOR
The MP180 Multi-Planer must be connected to a chip extractor with a total capacity of at least
2 000m
3
/h. Remember that the chip container has to be equipped with an air vent (e.g. a fine net or filter
if dust is collected indoors). Poor suction is often caused by poor airflow from the chip container. During
work in heated rooms, it is necessary to remember that the fan will quickly cool the space if the filtered
air is not supplied back into the building. The fire risk and dust emissions (discharge) must be considered
because of chip collection.
WARNING! There is a risk of fire and dust emission because of chip
collection.
Contact the local authorities for advice about designing the chip collection system to conform to the
national rules.
It is necessary to set the fan so that it is easy to reach the switch.
IMPORTANT! Remove the chips from the Multi-Planer when the work
is finished.
TECHNICAL REQUIREMENTS FOR THE CHIP EXTRACTOR
1
The chip extractor must be approved according to the CE standard.
The chip extractor hose diameters for the Multi-Planer = 100 mm (4”) x 2.
The pressure drop in the Multi-Planer is 20 mm column of water at 25 m/s.
The dust extractor airflow (“without external connection”) should be 2000 m
3
/h.
IMPORTANT! The dust extractor hoses must be grounded or made of
materials that do not accumulate an electrostatic charge.
CAUTION! Always turn on the chip extractor before starting the
machine.
1. EN 12779:2016-04 standard contains requirements for chip and dust extraction systems equipment with
fixed installations.