Maintenance
General maintenance after each use
Maintenance doc061821 4-1
4
SECTION 4 MAINTENANCE
WARNING! Before performing service, lock out the electrical ser-
vice as described in section 2.4. Failure to do so could result in
death or serious injury.
Refer to Online Manuals for electrical schematics.
4.1 General maintenance after each use
1. Check for debris impeding any moving parts.
2. Clean debris off of the motor or engine and fuel tank.
3. Check engine oil per motor/engine manufacturer’s manual specifications.
4. Check that the tire pressure are between 50-55 psi.
5. Check gearbox oil level per gearbox manufacturer’s manual specifications.
IMPORTANT! DO NOT OVERFILL THE GEARBOX. The gearbox
is mounted in the B7 wall mounting position. In this mounting posi-
tion the unit requires 6.1 PINTS of oil.
Recommend lubricants are:
4.2 Tracking the blade
WARNING! Before performing service, lock out the electrical ser-
vice as described in section 2.4. Failure to do so could result in
death or serious injury.
1. Open the wheel covers to observe the blade on the drive wheels.
2. Loosen the lock nuts on the tensioner.
Mobile (Mobilgear 630) Citgo (EP Compound 220)
Castrol (Alpha SP220) Shell (Omala 220)
Texaco (Meropa 220) Chevron (Gear Compound EP ISO2200)