Woodward easYgen-2000 User Manual

Woodward easYgen-2000
339 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
37427
Configuration
Software Version 1.xxxx
Manual 37427
easYgen-2000 Series
Genset Control

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Woodward easYgen-2000 and is the answer not in the manual?

Woodward easYgen-2000 Specifications

General IconGeneral
Digital Inputs8
Digital Outputs6
Communication ProtocolsModbus RTU
DisplayGraphic LCD
Protection DegreeIP20
ModeleasYgen-2000 Series

Summary

Chapter 2. Configuration

Configuration Via The Front Panel

Explains how to operate the unit via the front panel, covering button functions and display meanings.

Configuration Using The PC

Details the process of installing and using the Woodward ToolKit software for PC-based configuration.

Chapter 3. Parameters

Enter Password

Describes the multi-level password access hierarchy, allowing different degrees of access to parameters.

Configure Measurement

Allows configuration of measurement settings, including generator type, frequency, voltage, and current transformer details.

Configure Monitoring: Generator

Generator voltage monitoring

Defines the type of monitoring for generator voltage, choosing between phase-neutral or phase-phase measurement.

Configure Monitoring: Generator, Overfrequency (Levels 1 & 2) ANSI# 81O

Configures two alarm levels for generator overfrequency monitoring with definite time alarms.

Configure Monitoring: Generator, Undervoltage (Levels 1 & 2) ANSI# 27

Configures two alarm levels for generator undervoltage monitoring with definite time alarms.

Configure Monitoring: Mains

Configure Monitoring: Mains, Underfrequency (Levels 1 & 2) ANSI# 81U

Configures two alarm levels for mains underfrequency monitoring with definite time alarms.

Configure Monitoring: Engine

Configure Monitoring: Engine, Start Failure

Monitors engine start attempts, triggering an alarm if the engine fails to start within configured attempts.

Configure Monitoring: Engine, Shutdown Malfunction

Monitors engine shutdown process, triggering an alarm if the engine fails to stop within the configured time.

Configure Monitoring: Breaker Monitoring

Configure GCB

Configures circuit breaker monitoring for GCB reclose and open alarms, including related parameters.

Configure Synchronization GCB

Configures synchronization parameters for the GCB, including timeout, alarm class, and self-acknowledgement.

Configure MCB {2oc}

Configures circuit breaker monitoring for MCB reclose and open alarms, including fault and logic settings.

Configure Monitoring: Flexible Limits

Flexible limits monitoring

Configures flexible limits for monitoring analog inputs, allowing custom alarm and control settings.

Configure Monitoring: Miscellaneous

Configure Monitoring: Miscellaneous, Battery, Overvoltage (Levels 1 & 2)

Configures two alarm levels for battery overvoltage monitoring, with definite time alarms and adjustable limits.

Configure Application

Configure Application: Configure Breakers

Configures breaker settings like application mode, transition modes, and dead bus detection.

Configure Application: Configure Inputs and Outputs

Configures input and output settings, including analog inputs, discrete inputs, and relay outputs.

Configure Application: Configure Engine

Configures engine settings such as type, start/stop sequences, idle mode, and emergency run parameters.

Configure Application: Automatic

Configures automatic operation modes, including start/stop logic, load-dependent start/stop, and generator selection.

Configure Application: Configure Controller

Configures controller parameters for voltage, frequency, load, and power factor control.

J1939 Interface

Configure LogicsManager

Configure Counters

Appendix A. Miscellaneous

Appendix E. Triggering Characteristics

Appendix G. LDSS Formulas