7
CONTROLS
6 720 803 801 (2012/09)
3.1 OPERATING THE BOILER
3.1.1 BOILER DISPLAY
This is typical of the display when the boiler is not supplying a central heating or hot water demand.
The display will not be backlit and the internal temperature of the boiler is displayed.
When heat is demanded and the boiler fires up, the flame symbol will be displayed.
3.1.2 SETTING THE BOILER FLOW TEMPERATURE FOR THE CENTRAL HEATING SYSTEM
1. Turn the central heating temperature control knob to the desired flow temperature between 30 and 82°C, this will be indicated
on the digital display. This is not the room temperature but the flow temperature through the radiators.
The “e” point provides guidance for the maximum temperature setting for optimum energy efficiency.
2. The radiator symbol will be displayed to confirm that the a central heating setting is being changed.
3. The value is displayed during this process, press to exit or after five seconds of inactivity the boiler display will return to the
default screen.
B Comfort levels within rooms should be controlled by your thermostatic radiator valves and/or room thermostat.
3.1.3 BOILER FROST PROTECTION
If you are leaving your property unoccupied during cold weather, please leave your programmer on constant and your room
thermostat set to 15°C.
B If the temperature within the boiler falls below 8°C the pump will run to circulate water and prevent the system freezing.
If the temperature does not rise to 9°C within 30 minutes of the pump operating, the boiler will fire up to provide heat to bring
the temperature up.
B If the temperature within the boiler falls below 5°C the boiler will fire immediately, bringing the boiler temperature up to 12°C to
avoid the possibility of the system freezing.
B This process will be repeated until such time that the boiler temperature does not drop below 5°C.
max
min
2
3
1
04
bar
1
ok
eco
reset
e
max
min
°C
°F
PreHeat
°C
°F
PreHeat
6720643358-13.1Wo
ok
max
min
2
3
1
04
bar
1
ok
eco
reset
e
max
min
°C
°F
Eco
1.
6720643358-03.1Wo
°C
°F
Eco
2.
3.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester Greenstar CDi Compact Series and is the answer not in the manual?

Worcester Greenstar CDi Compact Series Specifications

General IconGeneral
ModelGreenstar CDi Compact Series
CategoryBoiler
TypeCombination
Efficiency RatingA
Fuel TypeNatural Gas
MountingWall-mounted
EfficiencyUp to 94%
Weight34kg
Dimensions (HxWxD)700mm x 420mm x 330mm

Related product manuals