SERVICING
& SPARES
INSTALLATION & SERVICING INSTRUCTIONS
REPLACEMENT PARTS
8 716 115 216b (09.2008)
39
REPLACEMENT PARTS
Sensors:
Check that the appliance is electrically
isolated.
Flow temperature sensor (A):
Remove the connector.
Release the sensor clip and withdraw
the sensor.
Apply heat transfer paste to the
replacement sensor.
Safety temperature limiter (B):
Remove the connectors.
Unscrew the sensor.
Flue Temperature limiter (H):
Remove the connector.
Unscrew the sensor.
A
B
H

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester Greenstar FS 30CDi Regular and is the answer not in the manual?

Worcester Greenstar FS 30CDi Regular Specifications

General IconGeneral
ModelGreenstar FS 30CDi Regular
CategoryBoiler
Output30 kW
Fuel TypeNatural Gas
Max Working Pressure3 bar
Warranty5 years