CENTRAL HEATING FUNCTION
INSTALLATION & SERVICING INSTRUCTIONS
8 716 115 216b (09.2008)
BOILER FUNCTION
46
FAULT FINDING
& DIAGRAMS
FAULT FINDING
& DIAGRAMS
NO
YES
POWER
SWITCH
ON
DE MAND
Fan to
start
speed.
Pump ON.
IGNITION
SEQU EN CE
(see detail)
BLUE
LIGH T
ON
BURNER
LIT?
GREEN
FLAME
LI
GHT
ON
Stop spark.
Wait
10 seconds
5th
attempt?
LOCK OUT
10 second
stabilisation
period.
Fan (& gas)
modulation
to achieve
set
temperature
(40-82 °C)
EN D OF
BO ILER
DE MAND
Gas valve
OFF
Pump run 3
minutes
Fan run 30
seconds
Over temperature shut-
down if water tempera-
ture is 5°C above set
value.
Gas valve OFF.
Fan overrun
30 seconds
3 minute wait
Spark
ignition
4 seconds
NO
YES
Room
thermostat and/or
mains
programmer ON
and TEMP
control knob ON
IG NITION SEQ UE NC E
DING
AMS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester Greenstar FS 30CDi Regular and is the answer not in the manual?

Worcester Greenstar FS 30CDi Regular Specifications

General IconGeneral
ModelGreenstar FS 30CDi Regular
CategoryBoiler
Output30 kW
Fuel TypeNatural Gas
Max Working Pressure3 bar
Warranty5 years