ADVANCED OPERATION
5
6
7
8
7
8
iii. COM CTL Control
After fully connecting all inputs and outputs to the matrix
and installing the software, on opening the program
the control window will display information from the
matrix, such as messages received from the switch such
as input/output details, firmware version and control
commands/HEX codes that allow the system to be
controlled remotely, as well as buttons used to navigate
the screen.
Receive Message Window – displays messages
received from the matrix, such as input/output settings
and command selections. You can view the current
condition of all input/output ports by pressing the
button.
Pressing
will delete the previous message received in the window.
Send Message Window – Input your serial
commands for the matrix in the Send Message Window
- such as instructions for outputs or to enter update mode
– and click the Send button to deliver the message to the
Matrix.
NOTE To see the firmware version currently used in
the system – power off and repower while the matrix is
connected to COM CTL. The firmware version and
creation date will be displayed together with the normal
output state of the matrix.
Set IP button non-functional – To set your IP,
please refer to Smart Set GUI on p.14 section 4
UTP Set – Default setting is OFF for normal Matrix
operation to obey device EDID/HDCP commands and
high hotplug settings when outputting a signal.
Switching output settings to ON instructs the matrix
to output a signal regardless of device EDID/HDCP
or hotplug data – such information is circumvented to
encourage communication in the event of problems
between sync devices.
We recommend this setting for system debugging by
the installer and not for operation by the end user.
IR Matrix
Select the
button to check current settings attached to the IR port.
Com Connect State - Shows if the matrix is
connected or disconnected to the Com Port and
communication is enabled. Selection between ports is
available by pressing the Com Port Select button.
When connected, the only option will be to Disconnect
and vice versa. Press to connect/disconnect the matrix
from the software control.
• Connected for matrix communication enabled
• Disconnected for matrix communication disabled
Com Select
Connect/Disconnect
Click the Com Select dropdown to see all Com ports
available. Select your chosen Com port number and press