975-0526-01-02 45
Accessing Charger Information
Reverse Polarity Fuse
fault
Check for reverse battery polarity (negative
connected to negative, positive connected to positive
is correct) at battery and charger output terminals.
Disconnect AC and DC sources before replacing the
fuse(s) on the charger. See “Replacing the DC Output
Fuse” on page 48.
Internal fault Call Xantrex for support.
Flashing LED Solid LED
Table 9
Interpreting Fault and Warning Indicators
Fault or Warning
Condition
Temp Fan AC Battery Fuse Charger Remote Fault
Solution